Drying and Recoat Timing Planlayıcı Tool

Adjust data-sheet timings to site temperature and organize the schedule for proposals.

Adjust data-sheet timings to site temperature and show earliest recoat, latest recoat guideline, and masking completion in one place.

Use °C / °F, and export a proposal-ready PDF from the same ekran.

Temperature adjustment
Recoat window
Masking completion
PDF export
Çok dilli

How to use

  1. Choose the temperature unit and basis, then enter the site temperature.
  2. Enter reference temperature, earliest recoat, latest recoat, and masking completion for each product.
  3. Optionally add the application start time and review the schedule timestamps.
  4. Review the sonuçlar, then copy, paylaşım the URL, or export PDF.

Sample

Viewing a 20°C primer at 30°C

Girdi
Proje: Exterior repaint / Site temp: 30°C / Reference temp: 20°C / Q10: 2.0 / Primer: 4-8h, masking 6h
Çıktı
Temperature factor 0.50, earliest recoat 2h, latest recoat 4h, masking complete 3h

Viewing a 77°F top coat at 59°F

Girdi
Proje: Shopfront repaint / Site temp: 59°F / Reference: 77°F / Q10: 2.0 / Top coat: 8-24h, masking 12h
Çıktı
Temperature factor 2.00, earliest recoat 16h, latest recoat 48h, masking complete 24h

Glossary

Reference temperature
The temperature at which the data-sheet timing was specified.
Q10
The time-change multiplier for a 10°C shift. With 2.0, a 10°C drop roughly doubles the time and a 10°C rise roughly halves it.
Earliest recoat
The earliest recommended time to apply the next coat.
Latest recoat guideline
The upper end of the recoat window. If exceeded, surface preparation may be required.
Masking completion
The tahmind time when protection or masking can be completed.

Formulas

  • temperatureFactor = Q10 ^ ((referenceTempC - siteTempC) / 10)
  • adjustedMinutes = referenceMinutes × temperatureFactor
  • targetTime = startTime + adjustedMinutes
  • Safe rounding: round earliest up, latest down, masking up

Notice (approximation only)

  • This is an tahmin. Always prioritize the product data sheet and site conditions.
  • Humidity, ventilation, film thickness, substrate temperature, sunlight, wind, and mix ratio are not modeled precisely here.
  • If the reference temperature or basis differs from the data sheet, match the same basis before entering values.
  • The meaning of a recoat deadline varies by product. Check whether prep is required after the window closes.

SSS

Which temperature unit should I use, °C or °F?

Use the unit used by the site and the data sheet. Switching units converts the values.

The data sheet is based on 25°C / 77°F. Can I enter 20°C instead?

No. Enter the reference temperature exactly as stated in the data sheet.

What if the product does not list a latest recoat guideline?

Enter the same value as the minimum or leave it blank. Missing values are shown as partial sonuçlar.

Can humidity be considered too?

Not in this initial version. Humidity is handled only as a caution note.

Can I reproduce the same inputs from a paylaşımd URL?

Yes. It restores the proje name, temperature conditions, rows, and ayarlar.

Can I use the PDF directly in a proposal?

Yes. The proposal layout is designed for print/PDF çıktı.