Mining calculator Works offline in the browser Supports m³/s, m³/min, and cfm Handles kW and hp inputs

Kalkulator Aliran Udara Ventilasi Bawah Tanah

Perkirakan kebutuhan aliran udara dengan cepat dari jumlah pekerja, jumlah alat diesel, daya, dan faktor kondisi.

Ini adalah estimasi awal untuk perencanaan dini, pelatihan, dan perbandingan. Bukan pengganti desain ventilasi final atau kepatuhan regulasi.

Safety note

All calculations stay in this browser and are not sent to any server.

  • For preliminary estimates, training, and comparison only. Not a substitute for final ventilation design or legal compliance.
  • Review gas, dust, heat load, oxygen deficiency, and post-blast dilution separately.
  • Adjust diesel condition factors to match site standards and equipment maker guidance.

How to use

Catatan

  1. Enter the worker count for the area you want to ventilate.
  2. Add one row per diesel equipment type and enter count, power, condition factor, and simultaneity.
  3. Open settings if you need to change airflow coefficients, minimum airflow, or decimal places.
  4. Check the governing criterion and the final recommended airflow in the result pane.

Contoh

Input / Output

Case 1: 8 workers / 1 LHD / 55 kW / 10% reserve

Input

Workers=8, equipment=LHD ×1, power=55 kW, condition=baseline, simultaneity=100%, local minimum=0

Output

About 3.8 m³/s / 229 m³/min / 8,100 cfm. Governing criterion: diesel equipment.

Case 2: 4 workers / 1 service truck / 30 kW / local minimum 120 m³/min

Input

Workers=4, equipment=service truck ×1, power=30 kW, condition=controlled, simultaneity=100%, local minimum=120 m³/min, reserve=10%

Output

About 2.2 m³/s / 132 m³/min / 4,700 cfm. Governing criterion: local minimum airflow.

Glosarium

Underground ventilation airflow calculation

Required airflow
The estimated amount of air that should be supplied to the underground working area.
Governing criterion
The largest requirement among personnel, diesel equipment, and local minimum airflow.
Simultaneity
The share of equipment that is expected to operate at the same time.
Condition factor
A reference factor that reflects differences in equipment condition or aftertreatment.
Reserve margin
An added percentage above the governing criterion to keep the estimate conservative.

Formulas

Internal calculations use m³/s as the base unit.

  • Q_people = N_people × R_people
  • Q_row = N_i × P_i × F_condition_i × F_simultaneity_i × R_diesel
  • Q_governing = max(Q_people, ΣQ_row, Q_local_min)
  • Q_design = Q_governing × (1 + reserve / 100)
  • 1 m³/s = 60 m³/min = 2118.88 cfm

Pertanyaan yang sering diajukan

Catatan

Can I use this for final ventilation design?

No. This is for preliminary estimates, training, and comparison. Final design must follow regulations, site standards, and professional judgment.

Does it support both m³/s and cfm?

Yes. The display can switch, and the internal calculation uses SI units.

What does the condition factor mean?

It is a reference factor for site standards, aftertreatment, maintenance state, and similar differences.

What if there are multiple diesel equipment types?

Add rows and enter the count, power, and factors for each equipment type separately.

Can I use it offline?

Yes. It runs entirely in the browser and does not use external APIs.

Catatan

Internal calculations use m³/s as the base unit.

  • Alat ini hanya memberi perhitungan referensi. Desain akhir harus memprioritaskan regulasi lokal, standar internal, dan kondisi pabrikan.
  • Sesuaikan koefisien kondisi dan pekerja dengan asumsi lokasi Anda.
  • Masukkan hanya peralatan yang benar-benar berjalan bersamaan jika Anda ingin perbandingan yang lebih mudah.
  • Semua perhitungan tetap di browser.