Kaevanduskalkulaator Works offline in the brauser Supports m³/s, m³/min, and cfm Handles kW and hp inputs

Kiire maa-aluse ventilatsiooni õhuvoolu kalkulaator

Quickly estimate nõutav õhuvool from tööline count, diisel seade count, võimsus, and seisund factors.

This is a preliminary estimate for early planning, training, and võrdlus. It is not a substitute for lõpp ventilatsioon design or regulatory compliance.

Safety märkus

All calculations stay in this brauser and are not sent to any server.

  • For preliminary estimates, training, and võrdlus only. Not a substitute for lõpp ventilatsioon design or legal compliance.
  • Review gas, dust, heat laadimine, oxygen deficiency, and post-blast dilution separately.
  • Adjust diisel seisund factors to match site standards and seade maker guidance.

Kuidas kasutada

Märkused

  1. Enter the tööline count for the area you want to ventilate.
  2. Lisa one row per diisel seade type and enter count, võimsus, seisund tegur, and samaaegsus.
  3. Ava seaded if you need to change õhuvool coefficients, miinimum õhuvool, or kümnendarv places.
  4. Check the governing kriteerium and the lõpp recommended õhuvool in the tulemus pane.

Examples

Sisend / Väljund

Case 1: 8 töölised / 1 LHD / 55 kW / 10% reserv

Sisend

Workers=8, equipment=LHD ×1, power=55 kW, condition=baseline, simultaneity=100%, local minimum=0

Väljund

About 3.8 m³/s / 229 m³/min / 8,100 cfm. Governing kriteerium: diisel seade.

Case 2: 4 töölised / 1 service veok / 30 kW / kohalik miinimum 120 m³/min

Sisend

Workers=4, equipment=service truck ×1, power=30 kW, condition=controlled, simultaneity=100%, local minimum=120 m³/min, reserve=10%

Väljund

About 2.2 m³/s / 132 m³/min / 4,700 cfm. Governing kriteerium: kohalik miinimum õhuvool.

Sõnastik

Maa-alune ventilatsioon õhuvool calculation

Nõutav õhuvool
The estimated amount of air that should be supplied to the maa-alune working area.
Governing kriteerium
The largest requirement among personnel, diisel seade, and kohalik miinimum õhuvool.
Samaaegsus
The jaga of seade that is expected to operate at the same aeg.
Seisund tegur
A viide tegur that reflects differences in seade seisund or aftertreatment.
Reserv margin
An added percentage above the governing kriteerium to keep the estimate conservative.

Formulas

Internal calculations use m³/s as the base unit.

  • Q_people = N_people × R_people
  • Q_row = N_i × P_i × F_condition_i × F_simultaneity_i × R_diesel
  • Q_governing = max(Q_people, ΣQ_row, Q_local_min)
  • Q_design = Q_governing × (1 + reserve / 100)
  • 1 m³/s = 60 m³/min = 2118.88 cfm

Frequently asked questions

Märkused

Can I use this for lõpp ventilatsioon design?

No. This is for preliminary estimates, training, and võrdlus. Lõpp design must follow regulations, site standards, and professional judgment.

Does it support both m³/s and cfm?

Yes. The kuva can switch, and the internal calculation uses SI units.

What does the seisund tegur mean?

It is a viide tegur for site standards, aftertreatment, maintenance state, and similar differences.

What if there are multiple diisel seade types?

Lisa rows and enter the count, võimsus, and factors for each seade type separately.

Can I use it offline?

Yes. It runs entirely in the brauser and does not use external APIs.

Märkused

Internal calculations use m³/s as the base unit.

  • This tool provides viide calculations. Lõpp design must prioritize kohalik regulations, internal standards, and manufacturer conditions.
  • Adjust the seisund and tööline coefficients to your site assumptions.
  • Enter only the seade that actually runs at the same aeg if you want easier comparisons.